glass possibilities
library       contact
 
               
 

appearance

order code type of glass

thickness

mm

U-value

W/m2.K

acoustic insulation

(Rw) dB

safety
 

modern

insulation++ 8,5 3,2 34 P2a
  moden isolerend glas High Performance Insulation (HPI) 6,2 1,4 30 -
             
             
 

(float glass)

production after 1960

 

         
 

classic

insulation+ 3,8 3,7 29 tempered
  klassiek isolerend glas insulation+ solar reflection 5,9
4,1
31 tempered
  insulation++ 7,5 3,3 33 P2a
  insulation++ extra thin 6,5 3,4 33 P1a
  insulation++ extra bright 6,9 3,4 33 P2a
 

(slight distortions)

production 1920 -1960

> VR 22.22 insulation++ extra distortions 8,6 3,2 34 P2a
  > VR 22.52 insulation++ extra sound insulation 8,5
3,2
37
P2a
    insulation++ extra sound insulation 14,4 3,0 40 P2a
    insulation++ extra secure 9,9 3,1 35 P5a
 

 

High Performance Insulation (HPI) 10,2 1,3 34 P1a
  High Performance Insulation (HPI) extra secure 14,8 1,3 35 P5a
  cylinder insulation++ 5,9+ 3,4 32 P1a
 

cilinder isolerend glas

High Performance Insulaion (HPI) 9,7+ 1,3 34 P1a
  High Performance Insulation (HPI) extra secure 14,1+ 1,3 36 P5a
     

 

other types or qualities of glass on request

>printable version

 

(strong distortions)

production before 1920

Actual sizes may vary on account of the manual production process.